Raypak No Heat Output

Raypak heat pump runs but does not heat the pool; water temperature does not increase.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect thermostat setting, 3‑way valves bypassing heater, Low refrigerant charge, Dirty evaporator or condenser coil

How to Fix / Troubleshooting

Safety first: Turn off power before adjusting internal components; do not handle refrigerant lines.

  • Verify mode and setpoint: Ensure the Raypak controller is in HEAT mode (not COOL or OFF) and that the set temperature is above current water temperature.
  • Check valve positions: Confirm that water is actually flowing through the Raypak heat pump and not bypassing it. Adjust any 3‑way valves so that most flow passes through the heater.
  • Clean coils: Remove debris from the evaporator (air intake) and condenser coils. Good airflow is essential for heat transfer.
  • Monitor temperature rise: Measure water temperature at inlet and outlet. A very small or zero temperature rise with long run times may indicate a refrigerant issue; contact a Raypak‑qualified HVAC technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heat Pump Refrigerant Circuit
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements