E01
Rheem Low Line Voltage / Under‑Voltage Lockout

Digital control will not start the pool pump; display shows E01 and pump does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incoming supply voltage below specification, Loose line or neutral connection at pump terminal block, Undersized wiring causing excessive voltage drop, Failing contactor or relay in Rheem control module

How to Fix / Troubleshooting

Safety First: Turn OFF power at the pool sub‑panel breaker and verify with a non‑contact voltage tester before opening any covers.

  • Check supply voltage: Remove the Rheem pump control cover. With a multimeter and power restored, measure voltage at the LINE terminals feeding the pump. Compare to the nameplate (typically 230V ±10%). If voltage is low, contact an electrician to correct the supply.
  • Inspect wiring connections: Turn power OFF again. Tighten all line, neutral, and ground screws at the pump terminal block and at any external Rheem control box or timer. Look for heat discoloration or melted insulation and repair/replace damaged conductors.
  • Check wire gauge and run length: If the pump is far from the panel and wired with small gauge wire, excessive voltage drop can trigger E01. Consult Rheem installation manual for recommended wire size and upgrade if needed.
  • Inspect internal relay/contactor: On models with an integrated Rheem control module, inspect the power relay or contactor for pitted or burned contacts. Replace the control module or relay assembly if contacts are damaged.
  • Reset the control: After corrections, turn power OFF for 2–3 minutes, then restore power and attempt to start the pump. If E01 persists with correct voltage, the control board may be defective.