E01
Speck Pumpen Undervoltage / Supply Power Fault

Pump will not start, digital controller shows E01 immediately after pressing ON.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incoming mains voltage too low, Loose supply terminal in control box, Defective main power switch on Speck controller, Tripped upstream circuit breaker or RCD

How to Fix / Troubleshooting

Safety first: Disconnect the pump from mains power at the breaker before opening any electrical box. Water and electricity are a lethal combination.

Steps to check:

  • Verify supply voltage: Use a multimeter at the pump’s supply terminals (inside the Speck control box or motor terminal box) to confirm the correct voltage (e.g. 230 V single-phase or 400 V three-phase as per nameplate). If voltage is below spec, contact an electrician.
  • Inspect breaker and RCD: Ensure the dedicated pool pump breaker is ON and the RCD has not tripped. Reset if necessary and try starting again.
  • Check terminal tightness: With power OFF, remove the cover of the Speck Pumpen control box and inspect L/N (and L1/L2/L3) terminals. Tighten any loose screws and look for signs of overheating or discoloration.
  • Inspect main power switch: If equipped with a rotary isolator or ON/OFF rocker on the Speck controller, check for mechanical damage or burning. Test continuity with a multimeter; replace if open when switched ON.
  • Check supply cable: Follow the cable from the distribution board to the pump. Look for crushed, cut, or water-damaged sections. Replace damaged cable immediately.

If correct voltage is present at the motor terminals and E01 persists, the controller’s power input stage may be defective and should be serviced or replaced by a qualified technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Speck Pumpen control box / power switch assembly