E04
Speck Pumpen Phase Loss / Phase Imbalance (Three-Phase Models)

Speck variable-speed pool pump controller shows E04 and the motor does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown fuse on one phase, Loose phase conductor at motor terminal block, Faulty contactor in Speck control panel, Supply issue from three-phase distribution board

How to Fix / Troubleshooting

Safety first: Only qualified persons should work on three-phase circuits. Isolate and lock out the supply before opening any panel.

Inspection steps:

  • Check upstream fuses: In the main distribution or Speck control cabinet, test all three fuses feeding the pump. Replace any blown fuse with the correct rating.
  • Inspect contactor: If the pump is controlled via a contactor, check for burned contacts or a stuck pole. Replace the contactor if one phase is not passing voltage.
  • Verify terminal connections: Open the motor terminal box and confirm L1, L2, and L3 are tight and free of corrosion. Tighten loose screws and clean terminals.
  • Measure phase-to-phase voltage: With power ON (by a qualified electrician), measure L1–L2, L2–L3, and L1–L3. All should be within tolerance and balanced.

If phase voltages are correct and E04 persists, the internal drive electronics of the Speck variable-speed controller may be faulty and require replacement.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Speck Pumpen three-phase control panel / contactor assembly