E09
Speck Pumpen Sensor / Feedback Error (Speed or Pressure Sensor, if equipped)

Controller intermittently shows E09; pump speed fluctuates and sometimes stops unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose speed feedback connector between motor and controller, Faulty Hall sensor or tachometer in Speck motor, Damaged pressure or flow sensor wiring, Corroded low-voltage terminals

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing sensors or wiring.

Check connections:

  • Motor feedback cable: On variable-speed Speck pumps, locate the low-voltage feedback cable from the motor to the controller. Ensure both ends are firmly seated and free of corrosion.
  • Inspect sensor wiring: If a pressure or flow sensor is installed, check the cable for cuts, UV damage, or rodent bites.
  • Clean terminals: Gently clean oxidized terminals with contact cleaner and a soft brush.

Test operation:

  • Restore power and run the pump at a fixed speed. If E09 returns, the internal sensor in the motor or the controller input circuit may be defective.

Replace the faulty sensor assembly or motor (if the sensor is integrated) according to Speck Pumpen service documentation.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Speck motor with integrated speed sensor / feedback harness
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements