Possible Causes

Incorrect wiring to Speck control input terminals, Disabled external control mode in settings, Faulty relay or dry contact in automation system, Damaged low-voltage control cable

How to Fix / Troubleshooting

Safety first: Isolate power before modifying control wiring.

Verification steps:

  • Check the Speck controller manual for correct terminals for external start/stop or speed control.
  • Confirm that the controller is configured to accept external commands (not locked in manual mode).
  • Test the automation relay or contact with a multimeter to ensure it closes when commanded.
  • Inspect the low-voltage cable for damage and correct polarity where applicable.

If wiring and automation outputs are correct, the controller’s input circuit may be defective and require replacement.