Speck Pumpen
Short Circuit or Ground Fault
Pump trips the circuit breaker or RCD immediately when switched on.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Water ingress into motor terminal box, Damaged insulation on motor winding, Crushed or cut supply cable, Moisture inside Speck control box
How to Fix / Troubleshooting
Safety first: Do not repeatedly reset a tripping breaker. Risk of fire or electric shock.
Inspection steps:
- Visually inspect the supply cable from panel to pump for cuts or crushed sections. Replace if damaged.
- Open the motor terminal box and check for water, corrosion, or loose strands touching the casing. Dry thoroughly and correct wiring.
- Open the Speck control box (if fitted) and look for moisture or burned components.
Testing:
- With the pump disconnected, see if the breaker still trips. If not, the fault is in the pump or its wiring.
- Insulation resistance testing of the motor windings to earth should be performed by a qualified electrician.
Replace the motor if insulation resistance is below acceptable limits.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Speck pool pump motor or supply cable
Check Price on Amazon
We may earn a commission from links on this page.