E11
Sta-Rite External Communication / RS-485 Error

Sta-Rite digital pump shows E11 and will not communicate with external automation system.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Reversed RS-485 polarity, Broken communication cable, Incorrect baud rate or protocol setting, Faulty automation interface on control board

How to Fix / Troubleshooting

Safety: Turn off power to both the pump and automation panel before working on low-voltage wiring.

  • Verify wiring: Check the RS-485 or communication terminals on the Sta-Rite pump and the automation system (e.g., Pentair/Sta-Rite controller). Ensure A/B (or +/–) are matched correctly and wires are firmly clamped.
  • Inspect cable: Look for cuts, splices, or corrosion in the communication cable. Replace damaged cable with twisted-pair, shielded wire as recommended.
  • Check settings: In the automation menu, confirm the pump type, address, and baud rate match the Sta-Rite pump's configuration.
  • Test standalone: Disconnect the automation cable and operate the pump from its local keypad. If E11 clears, the issue is in the external system or wiring. If E11 remains, the pump's communication interface may be faulty.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Sta-Rite pump control board / communication interface