Sta-Rite Failed Display / User Interface Power

Sta-Rite pool pump digital display is blank or very dim, but the motor still runs when controlled by external automation.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Burned-out LCD/LED display, Failed low-voltage regulator for display, Loose display ribbon cable, UV damage to keypad assembly

How to Fix / Troubleshooting

Safety: Disconnect power before opening the control housing.

  • Inspect connections: Remove the Sta-Rite control cover and check the ribbon cable between the display and main board. Reseat firmly.
  • Check for moisture and corrosion: Dry any condensation and clean light corrosion with contact cleaner.
  • Test external control: If automation still controls speed and schedule, the main board is likely functional and only the display/keypad assembly is faulty.
  • Replace keypad/display: Install a new Sta-Rite keypad/control cover assembly compatible with your model.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Sta-Rite pump keypad / display assembly
Check Price on Amazon