E4
Summer Waves Dry-Run Protection / No Water Detected

Control panel displays E4 and pump will not run or shuts down shortly after starting.

Advertisements

Possible Causes

Air leak on suction side, Pool water level too low, Inlet hose not fully submerged or blocked, Pump not properly primed

How to Fix / Troubleshooting

Safety First: Always unplug the pump before disconnecting hoses or opening the housing.

  • Check pool water level: Ensure the water level is above the minimum mark on the pool wall and fully covering the intake fittings.
  • Inspect suction hose connections: Tighten hose clamps at the pool wall fitting and pump inlet. Replace cracked or flattened hoses that may be drawing air.
  • Prime the pump: Remove the pump lid (if accessible) and fill the housing completely with pool water. Reinstall the lid, ensuring the O-ring is clean and lubricated. Open all valves fully.
  • Clear obstructions: Remove and clean the skimmer basket and any in-line strainers. Flush the suction hose with water to remove trapped air and debris.
  • Restart: Plug the pump back in and start it. If E4 returns immediately with good water level and no air leaks, the internal flow or dry-run sensor may be faulty and the control head may need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Suction Hose Assembly
Check Price on Amazon

We may earn a commission from links on this page.