E05
Waterway
Phase Loss / Single‑Phase Detection (for 3‑phase or inverter‑driven models)
Waterway digital pump display shows E05 and the motor will not run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose line conductor at terminal block, Blown breaker or fuse on one leg, Internal failure of inverter drive on control board
How to Fix / Troubleshooting
Warning: Only work on multi‑wire circuits if you are qualified. Turn off all breakers feeding the pump.
- Inspect terminal block: Remove the control cover and check that all line conductors are firmly secured to the Waterway pump terminal block. Tighten any loose screws.
- Check breakers/fuses: At the service panel, verify that all poles of the pump breaker are in the ON position and not tripped. Reset if necessary. If fuses are used, test each with a continuity tester.
- Measure voltage: With power on, measure between each pair of line terminals (L1–L2, etc.) to confirm balanced voltage. Any missing leg indicates a supply issue that must be corrected.
- Control board check: If supply is correct but E05 persists, the internal inverter or phase detection circuit on the control board may be defective. Replacement of the control board is typically required.