Zodiac Slow Air Ingress / Leak-Down

Pump does not hold prime overnight and must be re-primed each day.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Minor suction-side air leak, Check valve not holding (if installed), Lid O-ring seepage, Underground suction leak

How to Fix / Troubleshooting

Safety: Turn off power before inspection.

  • Replace lid O-ring: Even small imperfections can allow air in over time; install a new Zodiac lid O-ring.
  • Check suction check valve: If a check valve is installed on the suction line, inspect or replace it if it does not seal properly.
  • Tighten unions and fittings: Slightly tighten suction-side unions and inspect for hairline cracks.
  • Overnight test: Mark water level in pump basket at shutdown and check in the morning to see how far it drops, helping locate the leak source.

If the pump still loses prime, a professional leak detection service may be needed.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Pump Lid O-Ring
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements