Zodiac
Slow Air Ingress / Leak-Down
Pump does not hold prime overnight and must be re-primed each day.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Minor suction-side air leak, Check valve not holding (if installed), Lid O-ring seepage, Underground suction leak
How to Fix / Troubleshooting
Safety: Turn off power before inspection.
- Replace lid O-ring: Even small imperfections can allow air in over time; install a new Zodiac lid O-ring.
- Check suction check valve: If a check valve is installed on the suction line, inspect or replace it if it does not seal properly.
- Tighten unions and fittings: Slightly tighten suction-side unions and inspect for hairline cracks.
- Overnight test: Mark water level in pump basket at shutdown and check in the morning to see how far it drops, helping locate the leak source.
If the pump still loses prime, a professional leak detection service may be needed.