Zodiac Unstable Control / Sensor Feedback Issue

Pump speed fluctuates up and down on its own without changes to settings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Erratic flow or pressure sensor input, Loose control wiring, Electrical noise on power line, Failing control board

How to Fix / Troubleshooting

Safety: Turn off power before accessing control wiring.

  • Check automation commands: If connected to Zodiac automation, verify that no conflicting schedules or features are changing speed.
  • Inspect sensor wiring: Ensure flow or pressure sensor cables are secure and not damaged.
  • Secure power connections: Tighten line and neutral connections at the pump and panel to reduce electrical noise.
  • Factory reset: If allowed by the model, perform a factory reset of the pump controller and reprogram speeds.

If fluctuations persist, the control board may be failing and require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Pump Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements