F50
Asko Cooling Fan Fault

Asko range displays F50 and oven fan does not run during cooking or cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed oven cooling fan motor, Obstructed fan blades, Faulty fan relay on control board, Wiring fault to fan

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker and allow the oven to cool completely.

  • Access fan: Remove the top panel or rear panel (depending on model) to access the cooling fan assembly.
  • Inspect fan: Check that the fan blades spin freely by hand and that no insulation or wiring is obstructing them.
  • Check wiring: Ensure the fan’s connectors are secure and that there are no burned or loose wires.
  • Test fan (advanced): Apply appropriate voltage directly to the fan motor (only if qualified) to see if it runs. If not, replace the fan motor. If the fan runs on direct power but not during oven operation, the control board or fan relay may be faulty.

Do not operate the oven without a functioning cooling fan; this can overheat electronics and surrounding cabinetry.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Cooling Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements