F9
Asko
Configuration / EEPROM Error
Cooktop shows F9 and will not start any zones.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Corrupted control board memory, Incorrect replacement board not programmed for model, Power surge damage to logic circuit
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before accessing control boards.
- Power reset: Leave the cooktop unpowered for at least 10 minutes to fully discharge internal capacitors, then restore power and test.
- Check model label: Confirm the cooktop model number and compare with any recently replaced control board to ensure compatibility.
- Factory reset (if available): Consult the Asko service documentation for your model to see if a key combination can perform a configuration reset. This is usually for technicians only.
- Board replacement: If F9 persists, the main control board’s memory is likely corrupted and the board must be replaced with a correctly programmed Asko part.
Programming or coding of replacement boards may require Asko service tools; contact an authorized service center if needed.