F9
Belling Internal Configuration or Calibration Error

Induction hob shows F9, some or all zones inoperative

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control PCB firmware, incorrect configuration after power surge, failed touch control PCB, mis-matched replacement power module

How to Fix / Troubleshooting

Safety: Turn off power at the mains before any work.

  • Power cycle: Isolate the hob for at least 10 minutes to allow the control electronics to fully discharge. Restore power and test again.
  • Check installation: If a power module or control board was recently replaced, verify that the correct Belling part number was used and that all configuration jumpers or DIP switches (if present) are set according to the service manual.
  • Inspect touch control PCB: Remove the glass top and check the user interface board for moisture, corrosion, or cracked tracks. Clean any light contamination with isopropyl alcohol and a soft brush.
  • Service mode reset: Some models allow a factory reset via a key sequence; consult the Belling service documentation. If unavailable, or if reset fails, the control PCB may need replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Touch Control PCB
Check Price on Amazon

We may earn a commission from links on this page.