Belling Flame Failure Device (FFD) / Thermocouple Not Holding

Gas hob burner lights but goes out when knob is released

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty thermocouple on burner, misaligned flame not heating sensor, weak gas pressure, defective gas valve magnet

How to Fix / Troubleshooting

Safety: Gas components must be handled by a Gas Safe registered engineer in many regions.

  • Hold knob longer: Press and hold the control knob for 5–10 seconds after ignition to allow the thermocouple to heat fully. If the flame still goes out, continue below.
  • Clean burner and sensor: Ensure the flame failure sensor (small metal probe near the burner) is clean and directly in the flame. Clean with a soft brush.
  • Check flame quality: A very small or yellow flame may not heat the thermocouple enough. Have gas pressure and injector size checked by a professional.
  • Replace thermocouple or valve: If the flame is good but will not stay lit, the thermocouple or the gas valve magnet coil may be faulty and should be replaced by a qualified engineer.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Hob Thermocouple
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements