Bertazzoni Gas Leak in Range or Supply Line

Range emits strong gas smell when burners are off

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose gas connection at regulator, Damaged flexible gas hose, Leaking burner valve, Faulty pressure regulator

How to Fix / Troubleshooting

Safety first: Immediately turn off all burner knobs and shut off the gas supply at the main valve. Do not use electrical switches or open flames. Ventilate the area.

  • Do not operate: Do not use the range until the leak is located and repaired.
  • Leak detection: A qualified technician should apply a soap-and-water solution to all accessible joints (regulator, manifold, hose connections) to identify bubbles indicating leaks.
  • Tighten or replace: Tighten leaking fittings to the specified torque or replace defective components such as the regulator or flexible hose.
  • Valve inspection: If a burner valve is leaking internally, replace the valve assembly.

Warning: Gas leak diagnosis and repair must be performed by a licensed gas technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Pressure Regulator
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements