E7
Bosch
Glass Surface Temperature Sensor Error
Bosch induction cooktop shows E7 and will not allow operation of one or more zones.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty glass NTC sensor, Sensor detached from glass, Damaged wiring harness, Control board sensor circuit failure
How to Fix / Troubleshooting
Safety first: Turn off power and allow the glass to cool completely.
- Check for hot environment: Ensure the cooktop is not installed above an oven that is venting excessive heat directly onto the glass.
- Inspect sensor (advanced): Remove the glass and locate the surface temperature sensor. Verify it is firmly attached and wiring is intact.
- Test sensor: Measure resistance and compare to Bosch specifications. Replace if defective.
- Replace control module: If the sensor is good, the control module may be misreading temperature and should be replaced.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Glass Surface Temperature Sensor
Check Price on Amazon