Bosch Stuck Ignition Switch or Moisture in Switch Harness

Gas burners click continuously even when all knobs are in the OFF position on Bosch gas cooktop.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Spill or cleaning fluid in knob area, Shorted burner valve switch, Moisture in switch harness, Faulty spark module sensing circuit

How to Fix / Troubleshooting

Safety first: Turn off power to the cooktop to stop the sparking. Turn off gas if you smell gas.

  • Dry the area: Remove burner knobs and dry around the valve stems with a cloth. Allow several hours for internal switches to dry.
  • Test switches: Restore power and turn each knob on and off. If sparking starts when a specific knob is moved, that burner valve switch may be shorted.
  • Inspect switch harness: With power off, remove the top and inspect the ignition switch harness for moisture or corrosion.
  • Replace faulty switch: Replace the affected burner valve switch or entire switch harness if damaged.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Burner Valve Switch Harness
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements