Dacor Complete spark ignition system failure

All gas cooktop burners fail to ignite and there is no clicking sound

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No power to cooktop (tripped breaker), Failed spark module, Disconnected power harness to spark module, Faulty ignition switch harness on burner valves

How to Fix / Troubleshooting

Safety first: Ensure all burner knobs are OFF. Do not attempt to light burners manually until ignition is repaired.

  • Check power: Verify the circuit breaker for the range/cooktop is ON. Test a nearby outlet to confirm power in the area.
  • Listen for any spark: Turn each knob to the ignite position. If there is no clicking from any burner, the spark module may not be receiving power.
  • Access spark module: Remove the cooktop from the counter or lift the top (model dependent) to access the spark module. Check that the power connector is firmly attached.
  • Inspect ignition switches: The small switches on each burner valve send power to the spark module. Check the switch harness for disconnections or damage.
  • Replace spark module: If power and switches are good but no burners click, replace the spark module.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Cooktop Spark Module
Check Price on Amazon