F10
Dacor High temperature runaway or sensor out-of-range

Dacor oven shows F10 and may shut down heating unexpectedly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Oven temperature sensor reading erratically, Loose sensor connection at ERC, Stuck heating element relay, ERC temperature monitoring failure

How to Fix / Troubleshooting

Safety first: Turn OFF the breaker immediately if the oven overheats or will not shut off. Allow the unit to cool completely.

  • Check sensor and wiring: Test the oven temperature sensor resistance at room temperature and inspect wiring as described for F2/F3. Replace the sensor if readings are unstable or out of spec.
  • Inspect relays: Check the relay board or ERC for stuck or welded relays that may keep elements energized. Replace the board if any relay is suspect.
  • Verify ventilation: Ensure the oven cooling fan (if equipped) runs during high-temperature operation and that cabinet vents are not blocked.
  • Replace ERC if needed: If sensor and relays are good, the ERC may be misreading temperature and should be replaced.

Do not continue using the oven with an unresolved F10 error due to fire risk.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Temperature Sensor
Check Price on Amazon