F12
Dacor Internal control board configuration or EEPROM error

Dacor range shows F12 and disables oven functions

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted EEPROM on ERC, Incorrect or failed configuration data, Power surge damage to control board memory

How to Fix / Troubleshooting

Safety first: Turn OFF power at the breaker before handling the control board.

  • Power reset: Leave the unit powered OFF for at least 10 minutes, then restore power. Sometimes a full reset clears transient memory errors.
  • Check model configuration: Some Dacor controls require model-specific configuration after replacement. If F12 appeared after a board change, verify that the correct configuration procedure was followed (see service manual).
  • Replace ERC: If F12 persists, the ERC memory is likely corrupted. Replace the ERC with the exact Dacor part number for your model.

Configuration errors can cause unsafe operation; do not bypass or ignore F12.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Range Control (ERC)
Check Price on Amazon