F31
Dacor Cooktop surface temperature sensor open/short

Dacor cooktop shows F31 and one or more burners will not heat

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted thermistor on glass surface, Broken harness from sensor to control, Sensor dislodged from proper mounting position, Failed control board input

How to Fix / Troubleshooting

Safety first: Disconnect power and allow the glass surface to cool completely before disassembly.

  • Access sensors: Remove the cooktop from the counter and take off the bottom panel to locate the surface temperature sensors attached to the underside of the glass near each burner.
  • Check mounting: Ensure the sensor is firmly attached to the glass in the correct position. Reattach with high-temperature adhesive or clips if it has come loose.
  • Measure resistance: Test the suspect sensor with a multimeter at room temperature. Replace if open, shorted, or far from spec.
  • Inspect wiring: Follow the sensor leads to the control board, checking for pinched or burned wires. Repair as needed.
  • Replace control board: If sensors and wiring are good, replace the cooktop control/power board.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cooktop Surface Temperature Sensor