E0
Danby
Touch Control Communication or Calibration Error
Cooktop or range control displays E0 and may not respond to touch inputs.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loss of communication between touch panel and main board, Incorrect voltage supply to control, Static discharge or power surge, Loose harness between UI and power board
How to Fix / Troubleshooting
Safety first: Disconnect power at the breaker for at least 5 minutes before servicing.
- Power reset: Restore power after 5–10 minutes. If E0 clears and does not return, it may have been a transient glitch.
- Check supply voltage: Verify the range is receiving correct voltage (typically 240 V for electric ranges, 120 V for gas ignition) at the terminal block. Incorrect voltage can cause control errors.
- Inspect harness: Remove the control panel and check the wiring harness between the user interface (touch control) and the main power board. Reseat connectors and ensure no pins are bent.
- Replace faulty board: If E0 persists, either the touch control or main board is defective. Replace the user interface board first (most common), then the main control if needed.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
User Interface (Touch Control) Board
Check Price on Amazon