F5
Danby Control Board Relay or Watchdog Failure

Oven functions may be disabled, F5 error displayed, sometimes accompanied by beeping.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed relay on electronic oven control, Internal control board fault, Power surge damage, Poor neutral or line connection to control

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker. Capacitors on the control board may retain charge; avoid touching bare circuitry.

  • Power cycle: Turn off power for 5–10 minutes, then restore. If F5 reappears immediately, the control is likely defective.
  • Inspect wiring: Remove the rear control panel cover and verify all line (L1), neutral, and ground connections to the EOC are tight and not discolored or burned.
  • Check for visible damage: Look for burnt spots, cracked solder joints, or bulging components on the control board. Any such signs indicate replacement is needed.
  • Replace EOC: Order the correct Danby electronic oven control using the full model number. Transfer wires one at a time from old to new board, matching terminal labels.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Oven Control Board (EOC)
Check Price on Amazon

We may earn a commission from links on this page.