Er04
Fagor Power Supply / Overcurrent Fault

Induction zone shuts off and Er04 is displayed when trying to cook at high power.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect electrical connection (wrong phase or voltage), Loose terminal block connections, Defective power module, Internal short in induction coil

How to Fix / Troubleshooting

Safety first: This involves mains voltage. If you are not trained, contact a qualified electrician or Fagor service. Always isolate power at the breaker before opening any covers.

  • Check supply voltage: Verify that the hob is connected according to the Fagor wiring diagram (single‑phase or two‑phase as specified). Incorrect bridging on the terminal block can cause overcurrent errors.
  • Inspect terminal block: With power off, remove the rear or bottom cover to access the connection block. Check for burnt, loose, or discolored wires and tighten screws to manufacturer torque.
  • Test different zones: If Er04 occurs only on one zone, that zone’s power module or coil may be shorted.
  • Reset and test at lower power: After correcting wiring, reset power and test at medium power. If the error returns, the internal power module likely needs replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Induction Power Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements