F31
Fisher & Paykel Cooling Fan Over-Speed or Under-Speed Fault

F31 displayed, oven may shut down shortly after starting, fan may run at incorrect speed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect fan feedback signal, Failing fan motor, Loose fan blade on shaft, Control board fan driver fault

How to Fix / Troubleshooting

Safety first: Isolate power before accessing internal components.

  • Visual inspection: Access the cooling fan and check that the blade is firmly attached to the motor shaft and not slipping.
  • Check for obstructions: Ensure no insulation or wiring is interfering with the fan blades, which can alter speed.
  • Connector check: Reseat the fan connector at both the motor and control board ends.
  • Replace fan: If the fan is noisy, wobbles, or does not maintain speed, replace the fan assembly.
  • Control board: If a new fan does not resolve F31, the control board's fan driver or feedback circuit may be defective and require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Cooling Fan Assembly
Check Price on Amazon