Frigidaire Professional
Spark Ignition System Fault
Burners on gas cooktop click continuously and will not light or only some burners light
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Clogged burner caps or ports, Wet igniters from spills, Failed spark module, Cracked spark electrode, Loose ground connection
How to Fix / Troubleshooting
Safety first: Turn off gas supply and power before servicing. Avoid igniting gas if you smell a strong odor.
- Dry igniters:
- If a spill occurred, remove burner caps and let the area dry completely for several hours.
- Clean burners:
- Clean burner caps and ports with a soft brush; ensure caps are seated correctly.
- Inspect electrodes:
- Check each spark electrode for cracks or heavy buildup.
- Replace any damaged spark electrodes.
- Test spark module:
- If none of the burners spark, the spark module may have failed; replace it after verifying power and ground connections.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements