Er36
Gaggenau
Flex Zone Configuration / Coil Detection Error
Induction cooktop shows Er36 when using Flex or combined cooking zones
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect pan placement across flex zone, Faulty flex zone coil sensor, Loose coil harness, Power module firmware/configuration issue
How to Fix / Troubleshooting
Safety: External checks only unless you are a trained technician. Disconnect power before internal work.
- Reposition cookware: Ensure the pan covers the required area of the flex zone and is centered. Avoid placing very small pans across two coils.
- Use single large pan: For combined zones, use one large pan instead of two small ones.
- Power reset: Turn off the cooktop at the breaker for 5 minutes and retest.
- If Er36 persists on flex zone only: A technician should inspect the flex zone coil array and harness, and update or replace the power module if needed.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flex Zone Coil Array
Check Price on Amazon