Gaggenau Poor Ignition / Gas Flow or Flame Position Issue

Gas burner clicks but will not light, or lights only after several attempts

Advertisements

Possible Causes

Clogged burner ports, Misaligned burner cap, Low gas pressure, Dirty or cracked igniter electrode

How to Fix / Troubleshooting

Safety: Turn off the burner if it does not light within a few seconds to avoid gas buildup. Allow components to cool before handling.

  • Check burner cap: Ensure the burner cap is properly seated and centered on the burner base.
  • Clean burner ports: Remove the cap and burner head. Use a soft brush or wooden toothpick to clear debris from the gas ports. Do not enlarge the holes.
  • Clean igniter: Gently clean the igniter electrode with a soft brush or cloth to remove grease and residue.
  • Dry components: If there was a spill, dry the burner area thoroughly. Moisture can prevent ignition.
  • If problem persists on all burners: Have a technician check gas pressure and regulator settings specific to Gaggenau models.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Burner Head and Cap
Check Price on Amazon