F34
GE Profile
Cooling fan speed or feedback error
F34 error, oven fan or cooling system fault on some GE Profile wall-oven style ranges
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed cooling fan motor, Blocked fan blades, Faulty fan speed sensor or tach feedback, Wiring issue between fan and control
How to Fix / Troubleshooting
Safety: Turn off power and allow the oven to cool before servicing the fan.
- Listen for fan: When the oven is turned on, you should hear the cooling fan run. If silent, suspect the fan or power to it.
- Access fan: Remove the rear panel or top cover to reach the cooling fan assembly.
- Inspect blades: Check for insulation, wiring, or debris blocking the fan. Clear obstructions.
- Test motor: Use a multimeter to check for proper voltage at the fan when the oven is on. If voltage is present but the fan does not run, replace the fan motor.
- Check wiring and connectors: Repair any loose or burnt connections between the fan and control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Oven Cooling Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.