F6
Gorenje Relay Board / Power Module Communication Error

Oven display shows F6, some or all heating functions inoperative.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose harness between user interface and power module, failed relay board, low supply voltage, internal communication bus fault on Gorenje electronic control

How to Fix / Troubleshooting

Safety first: Turn off the appliance at the main breaker before removing any covers.

  • Check mains supply: Verify that the range is receiving the correct voltage (e.g., 230 V single-phase or 400 V 3N~ depending on model) at the terminal block. Loose connections can cause communication errors.
  • Inspect control connections: Remove the rear or top cover to access the electronic oven control and any separate power/relay modules. Ensure all multi-pin connectors are fully seated.
  • Look for damage: Examine the relay board for burned spots, cracked solder joints, or swollen capacitors. Any visible damage usually means the board must be replaced.
  • Power reset: After reseating connectors, leave the appliance powered off for 5–10 minutes, then restore power and check if F6 returns.

Warning: Live testing on control boards involves dangerous voltages. If you are not trained in electrical diagnostics, have a professional perform further checks and board replacement.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Power Relay Module / Electronic Control Board
Check Price on Amazon