F5
Haier Oven Control Board Relay or Configuration Fault

Haier oven displays F5 and will not start or complete a cycle

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed relay on electronic oven control, Incorrect wiring after installation, Internal control board fault, Power surge damage to control

How to Fix / Troubleshooting

Safety first: Disconnect power at the breaker. If recently installed, verify correct wiring against the installation manual.

  • Power reset: Leave the unit unpowered for 10–15 minutes to discharge the control. Restore power and see if F5 clears.
  • Inspect control board: Remove the rear panel behind the control. Look for burnt spots, cracked solder joints, or melted relay housings.
  • Check terminal block: Verify that L1, L2, and neutral are correctly connected and tight at the range terminal block. Loose connections can cause control errors.
  • Replace control board: If visual inspection shows damage or F5 returns immediately after reset, replace the electronic oven control (EOC) with a Haier-specified part.

If you are not comfortable working with high-voltage wiring, contact a licensed technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Oven Control Board (EOC)
Check Price on Amazon