Haier No Power to Control Panel

Haier range display and controls are dead, but power is present at the outlet

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on control board, Open thermal fuse, Loose wiring at terminal block, Failed control board power supply

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker before opening any panels.

  • Verify outlet: Confirm correct voltage at the outlet or junction box with a multimeter.
  • Inspect terminal block: Remove the rear cover and check for loose or burnt connections at the range terminal block.
  • Check internal fuses: Some Haier models have fuses on the control board or wiring harness. Test for continuity and replace with identical type and rating if blown.
  • Thermal fuse: Locate any inline thermal fuse protecting the control. Test and replace if open.
  • Control board: If fuses and wiring are good, the control board's power supply may have failed. Replace the oven control board.

Never bypass fuses; they are critical safety devices.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Oven Control Board (EOC)