Hansa
Incorrect Gas-Air Mixture / Burner Adjustment Fault
Gas burner flame is yellow, noisy, or lifting off the burner
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Wrong gas injectors for gas type, Blocked burner air inlets, Incorrect primary air adjustment, Low or high gas pressure
How to Fix / Troubleshooting
Safety first: Turn off the burner and allow it to cool before disassembly. Ensure good ventilation.
- Clean burner: Remove burner caps and heads. Clean all ports and air inlets thoroughly.
- Check flame color: After cleaning, relight. A correct flame is mostly blue with small yellow tips.
- Verify gas type: Confirm that the range is configured for the gas type in use (natural gas vs LPG) and that the correct Hansa gas injectors are installed. This must be checked by a gas technician.
- Adjust air (if applicable): Some burners have adjustable air shutters. A technician can adjust these to correct the flame.
Warning: Do not attempt to drill or modify injectors. Gas adjustments must be done by a licensed gas fitter.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Gas Burner Injector Nozzles
Check Price on Amazon