Hotpoint Shorted Infinite Burner Switch

Cooktop surface element stays on high and will not regulate temperature, even when knob is turned down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed infinite switch contacts welded closed, miswired replacement switch, shorted wiring between switch and element

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker immediately; a stuck-on element is a fire hazard.

Steps to check:

  • Do not use burner: Leave the affected burner off until repaired.
  • Access control panel: Remove the back panel behind the control knobs.
  • Inspect switch: Identify the infinite switch for the affected burner. Look for signs of overheating or melting.
  • Replace switch: Transfer wires from the old switch to the new one terminal-by-terminal, following the wiring diagram. Ensure correct connections.
  • Wiring inspection: Check for shorted or melted wires between the switch and element; repair as needed.

Warning: Do not continue using the range with a burner that will not shut off properly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Infinite Burner Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements