Hotpoint
Shorted Infinite Burner Switch
Cooktop surface element stays on high and will not regulate temperature, even when knob is turned down.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed infinite switch contacts welded closed, miswired replacement switch, shorted wiring between switch and element
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker immediately; a stuck-on element is a fire hazard.
Steps to check:
- Do not use burner: Leave the affected burner off until repaired.
- Access control panel: Remove the back panel behind the control knobs.
- Inspect switch: Identify the infinite switch for the affected burner. Look for signs of overheating or melting.
- Replace switch: Transfer wires from the old switch to the new one terminal-by-terminal, following the wiring diagram. Ensure correct connections.
- Wiring inspection: Check for shorted or melted wires between the switch and element; repair as needed.
Warning: Do not continue using the range with a burner that will not shut off properly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Infinite Burner Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements