F9
Ilve
Door Lock Position Error After Self-Clean
Ilve oven displays F9 and door remains locked after self-clean
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Door lock motor not reaching full position, Bent lock latch or linkage, Faulty lock position switch, Control board not sensing lock feedback
How to Fix / Troubleshooting
Safety: Turn off power and allow the oven to cool fully before attempting to release the lock.
- Power reset: After cooling, turn power off for 5 minutes, then back on. Sometimes the lock will cycle and release.
- Manual release: Consult your Ilve manual for the location of the manual door lock release (often accessible from the top or rear). Use a tool to gently move the release lever.
- Inspect lock assembly: Once the door is open and power is off, access the lock motor and linkage. Look for bent parts or obstructions.
- Switch test: Test the lock position switches for continuity in locked and unlocked positions. Replace the lock assembly if switches are faulty.
- Control board: If the lock works mechanically but F9 persists, the EOC may not be reading the switch correctly and may need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Oven Door Lock Assembly
Check Price on Amazon