Indesit Stuck Ignition Switch or Shorted Ignition Circuit

Gas burners on Indesit cooktop click continuously even when flames are lit

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck or wet burner control switch, Moisture in ignition wiring, Shorted ignition electrode to burner body, Faulty spark generator stuck on

How to Fix / Troubleshooting

Safety: Turn off all burners and disconnect power to stop sparking. Ensure gas knobs are in the OFF position.

Steps:

  • 1. Dry the hob: If the hob was recently cleaned or a pan boiled over, moisture may be causing continuous sparking. Wipe dry and allow several hours to air dry.
  • 2. Check control knobs: Remove burner control knobs and inspect the ignition switches beneath for signs of water or grease. Clean gently and allow to dry.
  • 3. Inspect electrodes: Ensure electrodes are not touching the burner caps or metal parts directly, which can cause a constant spark path.
  • 4. Test switches: With power off, use a multimeter to check each ignition switch for proper operation (closed only when knob is pressed/turned). Replace any switch that remains closed.
  • 5. Replace spark generator: If switches and wiring are fine but the module continues to click, replace the ignition module.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ignition Switch Harness
Check Price on Amazon