F94
Insignia
Self-Clean Abort Due to Door Lock or Temperature Fault
Display shows F94 during self-clean and cycle aborts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Intermittent door lock switch, Over-temperature condition, Failing EOC, Loose lock harness connection
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and allow the oven to cool before inspection.
- Check door lock switch: Access the lock assembly and test the position switch for reliable operation as the lock moves. Replace the lock assembly if the switch is intermittent.
- Inspect cooling system: Ensure the cooling fan runs during self-clean and that vents are not blocked. Replace the cooling fan motor if it fails to operate.
- Check wiring: Reseat all connectors between the lock assembly, sensor, and EOC.
- Control board replacement: If mechanical components test good and F94 recurs, replace the EOC.