F1E1
JennAir
Keypad / User Interface Failure
JennAir range displays F1E1; keypad may be unresponsive
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted or open keypad, Damaged user interface board, Loose UI harness connection, Moisture intrusion
How to Fix / Troubleshooting
Safety: Turn off power before accessing the control panel.
- Dry and clean: If the error followed a spill or heavy steam, leave power off for several hours to dry. Clean the panel surface gently.
- Check harness: Remove the control panel and inspect the harness between the user interface (UI) and main control. Reseat all connectors.
- Inspect UI board: Look for corrosion or burn marks on the UI board. Replace if damaged.
- Replace UI / keypad: If F1E1 persists, install a new JennAir-compatible user interface or keypad assembly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Keypad Board