JennAir Broil Igniter Failure

Gas JennAir range broiler will not ignite; bake works normally (no error code)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open broil igniter, Weak broil igniter not drawing enough current, Loose broil igniter wiring, Failed broil gas valve coil

How to Fix / Troubleshooting

Safety: Turn off gas and power before servicing.

  • Check broil operation: Start a broil cycle and look for the igniter glow near the broil burner. If it does not glow or glows weakly and the burner never lights, suspect the igniter.
  • Access broil igniter: Remove the oven racks and broil shield to access the broil burner and igniter.
  • Test igniter: Inspect for cracks and test continuity. Replace if open or physically damaged.
  • Replace igniter: Install a new JennAir-compatible broil igniter, routing wires away from direct flame.
  • Gas valve check: If a new igniter glows strongly but the burner does not light, the broil gas valve may be defective and should be tested by a professional.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Broil Igniter
Check Price on Amazon

We may earn a commission from links on this page.