Kenmore
Ignition Spark Failure at Single Burner
Gas surface burner will not ignite, no clicking or spark at that burner
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed spark electrode at burner, Cracked porcelain insulator, Loose or broken ignition wire, Faulty spark module output for that channel
How to Fix / Troubleshooting
Safety first: Turn off gas supply and disconnect power before servicing. Avoid open flames while working on gas components.
- Basic cleaning:
- Ensure burner cap is properly seated.
- Clean food debris from around the electrode tip and burner ports.
- Check spark:
- Restore power (gas can remain off for this test).
- Turn the knob to Lite and observe if any spark appears at the electrode.
- If other burners spark but this one does not, suspect the electrode or its wiring.
- Inspect electrode and wire:
- Disconnect power again.
- Lift the burner head and inspect the electrode for cracks or heavy buildup.
- Check the ignition wire from electrode to spark module for damage or loose connections.
- Replace electrode:
- Install a new surface burner spark electrode if cracked or heavily corroded.
- Further diagnosis:
- If electrode and wire are good but no spark, the spark module may have a failed channel and should be replaced.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Surface Burner Spark Electrode
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements