Maytag
Surface Burner Ignition Failure
Gas surface burner will not ignite, clicking is heard but no flame
Advertisements
Possible Causes
Clogged burner ports, Misaligned burner cap, Weak spark at igniter, No gas to that burner valve
How to Fix / Troubleshooting
Safety first: Turn off burner knobs and ensure there is no gas smell before working. Do not use open flames to test for gas leaks.
- Check burner cap: Ensure the cap is properly seated and centered on the burner base.
- Clean burner: Remove the cap and burner head. Clean ports with a soft brush or a wooden toothpick (never metal) to clear debris.
- Inspect igniter: Make sure the igniter tip is clean and not cracked. Wipe with a dry cloth.
- Test gas flow: Light the burner with a long match or lighter (if safe and allowed by local codes). If it lights manually, the issue is ignition; if not, the gas valve or orifice may be blocked and should be serviced by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Gas Surface Burner Head and Cap
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements