E1
Monogram
Induction Module Overheat or Internal Fault
Induction cooktop displays E1 and disables one or more cooking zones.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked cooling vents under cooktop, Failed cooling fan for induction module, Overheated power board, Internal fault in induction power module
How to Fix / Troubleshooting
Safety first: Turn off the cooktop and allow it to cool. Disconnect power before removing any panels.
- Allow cooling: Turn off all burners and wait 20–30 minutes. Restart the cooktop to see if E1 clears.
- Check ventilation: Inspect the cabinet under the cooktop for blocked vents or insulation obstructing airflow. Ensure installation follows Monogram clearance requirements.
- Listen for fan: When a burner is on, you should hear the internal cooling fan. If not, the fan may have failed.
- Service module: If E1 recurs even with proper ventilation, the induction power module or cooling fan may need replacement by a qualified technician.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Induction Power Module
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements