Premier Stuck Door Switch or Relay

Oven interior light and fan (if equipped) stay on even when the door is closed and oven is off.

Advertisements

Possible Causes

Failed oven door switch stuck closed, Shorted light relay on EOC, Misaligned door not depressing switch

How to Fix / Troubleshooting

Safety First: Turn off power before working on the door switch or control board.

Step-by-step:

  • Check door alignment: Ensure the door closes fully and contacts the switch plunger.
  • Test door switch: Press the switch manually; if the light does not go off or the switch feels loose, replace the oven door switch.
  • Control board: If the switch tests good but the light/fan remain on, the EOC relay may be stuck. Replace the Electronic Oven Control (EOC).
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Oven Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements