SMEG
Ignition System Fault / No Spark
Gas cooktop with electronic ignition shows Er01 and burners will not ignite
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ignition module, Broken spark electrode, Loose electrode wiring, Moisture on ignition components
How to Fix / Troubleshooting
Safety first: Turn off gas supply at the shutoff valve and disconnect power. Allow any gas smell to dissipate before working.
Steps:
- Dry components: If the cooktop was recently cleaned, moisture may be causing the error. Allow the unit to dry for several hours or use a hair dryer on a low setting around the burners (power disconnected).
- Check electrodes: Remove burner caps and inspect the ceramic spark electrodes for cracks or heavy buildup. Clean gently with a soft brush.
- Inspect wiring: Under the cooktop, check that each electrode wire is firmly connected to the ignition module and not damaged.
- Ignition module: If there is no clicking on any burner when turned on (with power restored), the ignition module is likely faulty and should be replaced.
Warning: After any gas work, check all connections for leaks with a soapy water solution before use.