F08
SMEG
Cavity Cooling Fan Circuit Fault
Oven display shows F08 and cooling fan runs continuously or not at all
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed cooling fan motor, Stuck fan relay on control board, Shorted wiring, Faulty temperature sensor controlling fan
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before accessing rear panels.
Steps:
- Check fan operation: After a normal cooking cycle, the cooling fan should run then stop when cool. If it never runs or runs constantly, proceed.
- Access fan: Remove the rear panel to access the cavity cooling fan. Inspect for obstructions and spin the fan by hand.
- Test motor: Measure motor resistance and check for supply voltage when the oven is hot (qualified person). Replace the fan motor if it does not run when powered.
- Control board: If the fan runs constantly even when cold, the control board relay may be stuck closed and the board should be replaced.
Warning: Overheating due to a failed cooling fan can damage electronics and surrounding cabinetry.