SMEG Flame Failure Device Not Holding

Gas burner goes out when knob is released (must hold knob in to keep flame)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak thermocouple, Misaligned thermocouple tip, Loose thermocouple connection at valve, Faulty flame failure gas valve

How to Fix / Troubleshooting

Safety first: Turn off gas supply before working on thermocouples or valves.

Steps:

  • Align thermocouple: Ensure the thermocouple tip is directly in the flame when the burner is lit. Gently bend it closer if needed.
  • Clean tip: Lightly clean the thermocouple tip with fine abrasive pad to remove oxidation.
  • Check connection: Under the cooktop, tighten the thermocouple nut at the gas valve.
  • Replace thermocouple: If the flame still goes out when you release the knob, replace the thermocouple.
  • Valve replacement: If a new thermocouple does not solve the issue, the safety valve may be defective and should be replaced by a professional.

Warning: Always leak-test gas connections after reassembly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Burner Thermocouple
Check Price on Amazon