F8
Tecnogas
Power Supply / Relay Board Error
Tecnogas oven displays F8 and may not start or may shut off during operation.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low or unstable mains voltage, Failed power relay on control board, Loose connection at terminal block, Burnt wiring
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker.
Steps:
- Inspect the main terminal block where the power cord connects to the range. Tighten any loose screws and look for heat damage.
- Verify that the supply voltage matches the Tecnogas rating plate using a multimeter (only if qualified).
- Inspect the control board for burnt relays or tracks.
If the supply and wiring are correct, but F8 persists, the relay/control board likely needs replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Power / Relay Control Board
Check Price on Amazon
We may earn a commission from links on this page.